BCBBN - IRIDITE 14-2
- MSDS: BCBBN
- Manufacturer: ALLIED CHEMICAL CORP
- Product Name: IRIDITE 14-2
- National Stock Number: 6850-00K000558
Product Identification
Product ID:IRIDITE 14-2
MSDS Date:01/01/1985
FSC:6850
NIIN:00K000558
MSDS Number: BCBBN
Responsible Party
MORRISTOWN, NJ 07960
US
Cage: 1L168
Contractor
Telephone: 201-455-4414
Cage: 1L164
Ingredients
CHROMIC ACID(MIXTURE), 30%HEXAVALENT CHROME BASIS
RTECS: GB2650000
Fraction By Weight: UNK
ACGIH TLV: 25 UG/CUM
FLUORIDE
Fraction By Weight: 9%
METALLIC CHROMATE
Fraction By Weight: UNK
OSHA PEL C, 0.1 MG/M3 (CRO3)
ACGIH TLV: 0.05 MG/M3 (CR);8990
FERRIC CYANIDE SALT
Fraction By Weight: 10%
Hazards
Effects of Overexposure:SKIN:ULCERS;MUCOUS
MEMBRANES:ATTACKED,IRRITATION.
First Aid
First Aid:EYES,SKIN:IMMEDIATELY FLUSH EXPOSED AREA W H*2O FOR 15
MIN;REMOVE CONTAMINATED CLOTHING;INGESTED:GIVE MILK,INDUCE
VOMITING;GET MEDICAL ATTENTION. NOTE:TREAT SAME AS CHROMIC ACID.
Fire Fighting
Extinguishing Media:H*2O OR FOAM.
Fire Fighting Procedures:AVOID PERSONAL CONTACT & CONTACT W ORGANIC
MATERIALS.
Unusual Fire/Explosion Hazard:CONTACT W ALCOHOLS & SOME ORGANICS MAY
CAUSE SPONTANEOUS IGNITION.
Accidental Release
Spill Release Procedures:DO NOT TOUCH SPILLED MATERIAL. AVOID INHALING
DUST. SHOVEL INTO PVC/STAINLESS STEEL CONTAINER & COVER. NEUTRALIZE
RESIDUE W SODA ASH & WASH AREA W H*2O.
Handling
Handling and Storage Precautions:KEEP DRY(CORROSIVE WHEN WET);KEEP AWAY
FROM ORGANIC AND REDUCING AGENTS. TREAT AS ANY CHROMIC ACID
COMPOUND.
Other Precautions:DO NOT TAKE INTERNALLY, OR INHALE DUSTS OR MIST.
Exposure Controls
Respiratory Protection:DUST MASK
Ventilation:LOCAL EXHAUST TO ELIMINATE DUST/FUMES
Protective Gloves:TYPE AS REQD.
Eye Protection:SAFETY/CHEM GOGGLES.
Other Protective Equipment:RUBBER APRON & BOOTS.
Supplemental Safety and Health
MFG.BY KELITE PRODUCTS DIV: WILL CORRODE FE,AL,ZN,CU WHEN WET OR SOLN.
Chemical Properties
HCC:D1
Solubility in Water:APPRECIABLE
Appearance and Odor:REDDISH BROWN POWDER, NO ODOR.
Stability
Stability Indicator/Materials to Avoid:YES
AVOID ORGANICS, ALCOHOLS,& ANY REDUCING AGENTS.
Stability Condition to Avoid:ELEVATED TEMPERATURES ABOVE 150F.
Hazardous Decomposition Products:FIRE,ELEVATED TEMPERATURE MAY RELEASE
TOXIC FUMES.
Disposal
Waste Disposal Methods:TREAT AS CHROMIC ACID/HEXAVALENT CHROMIUM. DO
NOT RELEASE TO SEWER OR WATERWAYS. CONTACT SUPPLIER FOR DISPOSAL
METHODS. HANDLE/DISPOSE IN FULL REGULATORY COMPLIANCE
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.